Raypak
Raypak
Model Number: Raypak 147
Raypak® 147 is a compact, efficient heating design which is the ideal way to heat large quantities of water for both domestic hot water and hydronic applications.
- Available with modulating burners.
- Hot Surface Ignition (HSI) reduces operating costs
| Installation | Energy |
| Indoor/Outdoor | Gas |
Product Specifications
| DIMENSIONS AND TECHNICAL DATA TABLE – INDOOR/OUTDOOR MODELS | |||
| Natural |
– Input – Output |
MJ/h kW |
144 32 |
| LPG |
– Input – Output |
MJ/h kW |
135 30 |
|
Dimensions |
|
|
|
| Weight | kg | 71 | |
| Inlet/Outlet Connections | RC11/4 /32 | ||
|
Gas Connection Natural – On / Off Models Natural – Modulating Models LPG – On / Off Models LPG – Modulating Models |
|
||
|
Relief Valve Connection On/Off models Modulating models |
RC3/4/20 N/A |
||
| Electrical Rating 240V 50Hz |
Watts Amps |
50 0.21 |
|
| Min. Buffer Tank Capacity | Litres | 325 | |
| Max. Storage Capacity | Litres | 1,650 | |
| Natural Gas | |||
| Litres Recovery Per Hour @ | 30°C rise | 917 | |
| 40°C rise | 688 | ||
| 50°C rise | 550 | ||
| 60°C rise | 459 | ||
| 65°C rise | 423 | ||
| 70°C rise | 393 | ||
| 75°C rise | - | ||
| 80°C rise | - | ||
| 85°C rise | - | ||
|
Flow Rate and Pressure Drop Max. Flow Rate Modulating (10°C Rise)* Pressure Drop |
L/s |
0.76 |
|
|
Max. Flow Rate On/Off (15°C Rise)* Pressure Drop |
L/s kPa |
|
|
|
Min. Flow Rate (20°C rise)* Pressure Drop |
L/s kPa |
0.38 3 |
|

| GAS PRESSURE | |||
| Natural | Minimum | kPa | 0.95 |
| Test Point | kPa | 0.77 | |
| Maximum | kPa | 3.50 | |
| LPG | Minimum | kPa | 2.75 |
| Test Point | kPa | 2.75 | |
| Maximum | kPa | 3.50 | |
| THERMOSTAT SETTINGS | |||
| Modulating | Maximum | °C | 95 |
| Factory set | °C | 78 | |
| Minimum | °C | 44 | |
| On/Off | Maximum | °C | 80 |
| Factory set | °C | 50 | |
| Minimum | °C | 44 | |
| 17CLEARANCES COMBUSTIBLES (mm) | ||||
| Back | Front | Left | Right | Ceiling |
| 500 | 750 | 500 | 500 | 1,200 |
| 17CLEARANCES NONCOMBUSTIBLES (mm) | ||||
| Back | Front | Left | Right | Ceiling |
| 300 | 750 | 300 | 300 | 1,200 |
![]() |
Raypak® indoor gas water heaters are designed for connection to a flue system in accordance with the requirements of AS/NZS 5601.1. |
18 Expansion Control Valve is not supplied with the water heater.
19 Figures in brackets are to be used if a Raypak stainless steel storage tank is utilised in the system.
20 An 850kPa relief valve can be fitted to modulating water heaters used in potable hot water applications.
| ACCESSORIES FOR RAYPAK COMMERCIAL GAS WATER HEATERS | ||
| Accessories | Standard | Optional |
| Pump Run on Timer |
modulating |
On/Off |
| Tankstat | - |
![]() |
| Hot Surface Ignition (HSI) |
![]() |
- |
| Electronic Ignition | - | - |
| Water Flow Switch | - | - |
| Relay Run and Fault Status | - | - |
|
Temperature and/or Pressure Gauge (modulating burner models only) |
- | - |
| Temperature Gauge (on/off models only) | - |
![]() |
| High Wind Top (outdoor installations only) | - |
![]() |
| Rear Water Connections |
![]() |
- |
| Left Hand Water and Gas Connections | - | - |
| Right Hand Water Connections | - | - |
| Right Hand Water and Gas Connections | - | - |
| Audible Alarm | - | - |
|
Ambient Air Sensor (modulating burner models only) |
- | - |
| MINIMUM SUPPLY PRESSURE | |||||||||||||||||
| System design and pump selection is critical when water heaters are connected to a low pressure water supply. Refer to the table below for minimum pressure equirements for Grundfos UPS series pumps. Minimum pressure requirements for TP series pumps depend on system characteristics and need to be calculated. Contact your pump supplier for details. | |||||||||||||||||
|
|||||||||||||||||
|
UPS20-60N UP20-45N |
0.5 | 0.5 | 0.5 | 3.0 | 5.0 | ||||||||||||
| WATER SUPPLY AND RELIEF VALVE SETTINGS | |||||||||
| Burner Type | On/Off | ||||||||
|
Relief Valve Setting Potable Hot Water Mechanical Heating |
kPa kPa |
850 (700)19 - |
|||||||
|
Expansion Control Valve (ECV18) Setting Potable Hot Water Mechanical Heating |
kPa kPa |
700 (550)19 - |
|||||||
|
Maximum Supply Pressure without ECV18 Potable Hot Water Mechanical Heating |
fitted kPa kPa |
680 (550)19 - |
|||||||
|
with ECV18 fitted Potable Hot Water Mechanical Heating |
kPa kPa |
550 (450)19 - |
|||||||
| RAYPAK MODEL NUMBERS | ||||||
| The following information should be supplied when ordering Raypak water heaters | ||||||
| B | 0868 | N | C | O | / | ID |
|
Water Heater |
Approx Thermal Input* |
N = Natural Gas P = Propane |
Copper Heat Exchanger |
O = On/Off M = Modulating |
ID = Indoor OD = Outdoor HWT = High Wind Top |
|
Note: *last digit designates series type.


modulating



.jpg)